The Model SL-3 stainless steel sealed liquid cell has been designed to permit accurate alignment of the cell components. Alignment is accomplished by placing the front plate face down on a block of wood or other object about 3/4' thick and then placing the front lead gasket with holes in alignment with the hypodermic ports. The front drilled window is then placed in position over the ports, which are still visible. The amalgamated spacer, rear window, neoprene gasket and back plate can then be positioned without difficulty to seal the cell. The front gasket and front plate of the SL-3 are amalgamated permanently.
The aperture of the dispersive cell is 22.5mm x 10mm. The window size is 38.5mmx19.5mmx4mm.
A calibration charge of $23.40 is automatically added to the price of the cell, unless the customer expressly specifies that calibration is not required. Pathlengths for cells that are not calibrated are nominal and ICL assumes no responsibility for the customer's inability to calibrate the cell or for the failure of an uncalibrated cell to exhibit satisfactory fringing.
Add $23.40 for cell calibration (0010-186), $53.00 per cell for calibration and matching of .05mm, .1mm, .2mm, .5mm and 1mm cells (0010-185) and $71.00 per cell for calibration and matching of .015mm and .025mm cells (0010-4170). If you require calibration or calibration and matching and do not list it as a separate line item, the applicable charge will be charged to your credit card and will appear on your final invoice as a separate line item.
Pathlength |
N/A 0.015 mm0.025 mm0.05 mm0.1 mm0.2 mm0.5 mm1.0 mm |
Cell Calibration |
N/A Calibration Calibration and Matching No calibration |
Aperture |
N/A Rectangular Aperture - Dispersive |
Material |
N/A NaCl |
N/A
The Model SL-3 Stainless steel sealed liquid spectrophotometer cell ensures accurate visual alignment of the cell components. These cells never have partially blocked filling ports and they never leak. The SL-3 is assembled by placing the front plate face down and then placing the front lead gasket with holes in alignment with the luer lock syringe filing ports. The front drilled window is then placed in position over the ports which are still visible. The mercury amalgamated spacer, rear window, neoprene gasket and back plate can then be positioned without difficulty to seal the cell. All steel plates used in the cell are lapped optically flat to ensure a perfect amalgam seal and accurate alignment. This is the reverse of most spectrophotometer cell designs, which do not insure accurate alignment. Configuration of one of the filling ports on the edge of the front plate facilitates proper filling and emptying of the cell and prevents liquid sample material from damaging the windows and also prevents breaking the amalgam seal. |