-
Infrared Accessories/Sample Preparation Accessories
infrared-accessories-
-
Infrared Cell Cleaner
The Infrared Cell Cleaner is an ideal method for removing samples and solvents from sealed liquid cells. This cleaner provides a convenient means for cleaning liquid cells and eliminates the cumbersome use of vacuum pumps and other extraction apparatus.
-
Finger Cots
Finger Cots
(3)Finger cots are the preferred means for handling all optical windows and cells and for polishing or grinding optical windows. They are reusable, which makes them more economical than gloves.
-
PTFE Coated Stainless Steel Micro Spatula
PTFE coated nickel stainless steel micro spatula. For use with KBr and other SpectroGrade™ powders. We have found that this PTFE coated stainless steel spatula is ideal for handling KBr and other SpectroGrade™ powders when pressing pellets.
-
Desiccator Jar & Desiccator Cabinet
Desiccator jars are a must in all infrared laboratories. These jars are used for desiccating small samples, optics, cells and other applications. Complete with Bell jar, sealing ring, and polycarbonate cover.
-
Paper Inserts
Paper Inserts
(5)Use of paper inserts facilitates mounting small samples and pressing KBr pellets. Paper inserts are used to make KBr pellets by dropping them into the bore of a 13mm die set. The OD of the insert is slightly less than 13mm. Several hole sizes are available to enable formation of pellet from limited sample quantities. These inserts frame the pellet for ease of handling and also provide a visual reference for the proper amount of KBr powder which improves pellet quality and consistency.
-
Tweezers / Forceps & Eye Dropper
Stainless steel forceps with very sharp and fine points are ideal for handling KBr pellets and picking up minute samples. They can be used with micro samples being analyzed with an FTIR microscope or a single bounce HATR micro-sampler such as the Split-Pea™.
-
Spectrophotometer Recording Pens
Perkin-Elmer Pens - Nylon-tip disposable pens
Beckman Pens - Disposable pens -
Flow Cell Adapters
ICL offers a variety of Flow Cell adapters that will attach to standard IR liquid cells.
-
Infrared Wire Grid Polarizers
Wire Grid Polarizers are useful for enhancing sensitivity in grazing angle measurements using specular reflectance accessories and for molecular orientation studies. Polarizers attenuate radiation from polarized lasers, polarize radiation from unpolarized lasers and can be used in pairs to both polarize and attenuate. ICL wire grid polarizers are available for wavelength ranges from 3µm to 15µm.
ICL's 25mm wire grid IR polarizers are available with 360º rotation stage holders that are mounted on 2" x 3" backplates. These rotating mounts render the polarizer suitable for use in any FTIR or IR spectrophotometer simply by sliding the mount containing the polarizer into the instrument's standard 2" x 3" slide mount fixture. The polarizer, which is itself permanently mounted in a black anodized aluminum ring, is easily inserted into and removed from the rotating holder without touching the face of the polarizer. When ordered with a mount, polarizers can be installed in the mount prior to shipping on the customer's request.
-
Agate Mortars and Pestles for Sample Preparation
ICL’s agate mortars and pestles are the ideal tool for grinding a matrix of a solid sample with KBr powder in preparation for making a transparent pellet free from spurious absorption peaks.
-
Cuvette Rack
This polypropylene 2 tier rack holds a dozen 10mm lightpath cuvettes. Steam autoclavable at 250°F (121°C). 4 5/8” length x 4 1/4” width x 4 3/8” height.
The Square Cuvette Holder is suitable for all cuvette style rectangular cells with a 10mm lightpath.
The Adjustable Cuvette Holder accepts rectangular cuvette style spectrophotometer cells with pathlengths ranging from 1mm to 50mm -
FTIR Purge Gas Generators
FTIR instrumentation for FTIR Gas Analysis requires an environment free from water and CO2 to protect the optical and electronic components and to assure high signal to noise ratios. This can be achieved by operating in a nitrogen environment or with a purge gas generator.
-
Laboratory Shears
Multipurpose stainless steel shears with large handles, 2” blade and excellent leverage. The lower blade has a serrated edge to avoid slippage. Shears cut a variety of materials including rubber and plastic tubing as well as lightweight sheet metal. Handles autoclavable to 120°C.
-
Cuvette Stirrers & Funnels
ICL offers 3 versions of Cuvette Stirrers.
Polystyrene Stirring Spatulas
Plunger Type Cuvette Mixer
Polypropolene Cuvette Funnel -
Polystyrene Calibration Films
U.S. Patent No. 6,594,008
In addition to standard polystyrene calibration films, ICL offers several other calibration options. Superior calibrations are performed with radially symmetric films which eliminate the orientation effects of extruded films used for NIST Standard 1921 calibrations. -
European Pharmacopoeia 2.2.24 Reference Standard
ICL's PhEur 2.2.24 Reference Standard is a calibration standard certified to conform to the requirements of Chapter 2.2.24 of the European Pharmacopoeia.
-
Crystal Polishing Kit
The Crystal Polishing Kit contains everything needed by the spectroscopist for repolishing and buffing most infrared transmission crystals and ATR Prisms including KRS-5.
-
Opticlear™ Optical Cleaning Suspension
Opticlear™is a suspension based cleaning system that peels contamination off the face of optics. It can be used on both coated and uncoated optics. Simply apply this cellulose based suspension to the surface of the optic and peel it off when the suspension is dry.