                                                                    Item # 0017-7525, Special Vessel Cell for Freon Free (Hexane) method, EPA 1664 to be used with Oil-in-Water Analyzer
                                                                
                                                            
                                                         | 
                                                     
                                                    
                                                        | 
                                                            
                                                                    List Price $304.00
                                                               
                                                            
                                                         | 
                                                     
                                                    
                                                        
                                                             
                                                         | 
                                                     
                                                
                                             
                                         | 
                                     
                                
                             
                             
                            
                                                            
                                    The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as as solvent. A special cell is an optional accessory for this freon-free technique. 
                                
     
     
                           
                         | 
                     
                 
             | 
         
                            
                                
                                     
                                     
                                 | 
                             
        
            
                 
                
             | 
         
        
            
                
                    
                        
                            
                                 
                                
                                        
                                            
                                                                    
                                                                        
                                                                            Water and hydrocarbons absorb in the near IR at 3.4 to 3.5 microns (2930 cm-1). By dissolving the oil content of a sample into fluorochlorocarbon (freon), which is nonabsorbing at 3.4 to 3.5 microns, and following the extraction procedure established in EPA methods 413.2 and 418.1, a working curve is prepared using blank solvent (freon) and known standards. Samples are then compared to the calibration curve in direct ppm readings shown on the instrument. Repeatability is ±1% on identical samples.
  The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as a solvent. A special cell is an optional accessory for this freon-free technique.
  Features And Specifications
  
- Fixed 3.42 micron wavelength and 30 cm-1 bandwidth allows quick 10 second analysis without unnecessary scanning. Response time is a maximum of 40 seconds in damping 2 mode. Furthermore, the operating range permits the use of stable coated quartz optics that are not subject to degradation over time.
 
- Digital readout in %T, absorbance or concentration. Ranges: 0-100% T; 0-2 absorbance units; and 0-1 and 0-0.1 concentration. Built in scale expansion. Direct ppm readout. Recorder output is provided for optional recorder.
 
- Built in curve linearizer. Higher concentrations easily calibrated. Small footprint requires minimal benchspace. Portable. Weight: 20 pounds. Dimensions: 14” W x 11” D x 10” H.
 
- PbSe Peltier cooled detector provides signal to noise ratio of > 2500 to 1, instrument stability (drift) < 0.01 absorbance units per hour and photometric accuracy of ±1%.
 
- Instrument is simple to master and use, requires no maintenance, purging or special atmospheres and is warranted for a full year. Source is enclosed to avoid open source hazards.
 
- Electrical: 115/230v, 50-60 Hz, 80 watts.
 
 
                                                                         | 
                                                                     
                                                                 
                                                                 
                                                                                            
                                         
                                     
                                
                             | 
                         
                    
                 
             | 
         
                        
                     
                 | 
             
            
        
     
                                             | 
                                         
                                        
                                        
                                            
                                                 
                                                 
                                                 
                                             | 
                                         
                                        
                                              | 
                                         
                                        
                                        
                                            | 
                                                
                                             | 
                                         
                                        
                                            
                                                 
                                             | 
                                         
                                    
                                 
                             | 
                         
                    
                 
             | 
         
    
 
             |