IR Spectrophotometer Total Hydrocarbon Analyzer
|
Shipping
|
Tax
|
Terms
Shopping Cart
0 Items
Request for Quote
0 Items
All Categories
>
Hydrocarbon TestingÂ
>
IR Spectrophotometer Total Hydrocarbon Analyzer
>
Item # 0017-7674
Item # 0017-7674, Calibration standards in Hexane 50 ml. 10, 50 & 250ppm to be used with the Oil-in-Water Analyzer
List Price $1,390.00
Printable Page
Email This Page
Save To Favorites
Please wait…
larger image
10, 50 & 250ppm to be used with the Oil-in-Water Analyzer
The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as as solvent. A special cell is an optional accessory for this freon-free technique.
Additional Information
Water and hydrocarbons absorb in the near IR at 3.4 to 3.5 microns (2930 cm
-1
). By dissolving the oil content of a sample into fluorochlorocarbon (freon), which is nonabsorbing at 3.4 to 3.5 microns, and following the extraction procedure established in EPA methods 413.2 and 418.1, a working curve is prepared using blank solvent (freon) and known standards. Samples are then compared to the calibration curve in direct ppm readings shown on the instrument. Repeatability is ±1% on identical samples.
The Model 2930 can also be used with hexane based EPA method 1664, which is an analysis technique that does not require the use of freon as a solvent. A special cell is an optional accessory for this freon-free technique.
Features And Specifications
Fixed 3.42 micron wavelength and 30 cm
-1
bandwidth allows quick 10 second analysis without unnecessary scanning. Response time is a maximum of 40 seconds in damping 2 mode. Furthermore, the operating range permits the use of stable coated quartz optics that are not subject to degradation over time.
Digital readout in %T, absorbance or concentration. Ranges: 0-100% T; 0-2 absorbance units; and 0-1 and 0-0.1 concentration. Built in scale expansion. Direct ppm readout. Recorder output is provided for optional recorder.
Built in curve linearizer. Higher concentrations easily calibrated. Small footprint requires minimal benchspace. Portable. Weight: 20 pounds. Dimensions: 14” W x 11” D x 10” H.
PbSe Peltier cooled detector provides signal to noise ratio of > 2500 to 1, instrument stability (drift) < 0.01 absorbance units per hour and photometric accuracy of ±1%.
Instrument is simple to master and use, requires no maintenance, purging or special atmospheres and is warranted for a full year. Source is enclosed to avoid open source hazards.
Electrical: 115/230v, 50-60 Hz, 80 watts.